Tag: AISI S BRACE FOR IMPACT! Bracing Design for Cold-Formed Steel Studs. While consideration of bracing is important for any. AISI S, the North American Standard for Cold-Formed Steel Framing – Wall Stud Design, to provide technical information and specifications for designing. Find the most up-to-date version of AISI S at Engineering

Author: Magal Akisho
Country: Serbia
Language: English (Spanish)
Genre: Life
Published (Last): 23 June 2016
Pages: 135
PDF File Size: 16.98 Mb
ePub File Size: 1.96 Mb
ISBN: 122-6-96428-785-5
Downloads: 35227
Price: Free* [*Free Regsitration Required]
Uploader: Tejas

Share URL Copy and paste the link below into emails, chats or browsers. He is credited with helping to pioneer and expand the use of cold-formed steel framing in structural and nonstructural applications.

However, rather than add to the complexity of the AISI Specification, it was decided that a new family of standards should be developed. Special inspections are not required for cold – formed steel light – frame Although the AISI Specification had gained acceptance and was in widespread use, there were a s21 of design issues that were not adequately addressed for this emerging market.

The Cold-Formed Steel Engineers Institute comprises hundreds of structural engineers and other design professionals who are finding a better way to produce safe and efficient designs for commercial and residential structures with cold-formed steel.

The document addresses the design for a C-shaped cross section as a flexural member and a compression member. Permanent link to this article: Connection design is limited to primarily a discussion of screw connections. The presenter is Roger A. Section Steel, Cold-Formed Steel Light-Frame Construction The design and installation of structural and nonstructural members utilized in cold – formed steel lightframe construction where the specified minimum Therefore AISI extended its standards development activity to support the growing needs of the cold-formed steel framing industry.

The aizi and explanatory language is identified by a vertical black line along the right margin. The webinar will benefit architects, engineers, building officials and contractors.

TOP Related Articles  LOS GIRASOLES CIEGOS ALBERTO MENDEZ PDF

It applies to the design and installation of structural members and connections utilized in cold-formed steel light-frame construction applications, including floor and roof systems, structural walls, shear walls, strap braced walls and diaphragms to resist in-plane lateral loads, and trusses for load-carrying purposes.

AISI S integrates the following AISI standards into one document for easy reference, and thus supersedes all previous editions of these standards: These applications include wall, floor and roof framing in a number of building types.

Light-frame shear wallsdiagonal strap bracing that is part of a structural wall and diaphragms used to resist wind, seismic and other in-plane lateral loads shall be designed in accordance with AISI S AISI serves as the voice of the North American steel industry ss211 the public policy arena and advances the case for steel in the marketplace as the preferred material of choice.

Powered by WordPress and the Graphene Theme. Trusses not part of a manufacturing process that provides requirements for quality aizi done under the supervision of a third-party quality control agency, shall be manufactured in compliance with Sections It is available for free download at http: Matsen was a widely respected structural engineer for more than 30 years and the founder and principal of Matsen Ford Design Associates, Inc.

Detached one- and two-family dwellings and townhousesless than or equal to three stories above grade planeshall be permitted to be constructed in accordance with AISI S subject to the limitations therein.

Design Documents » Wei-Wen Yu Center for Cold-Formed Steel Structures

AISI S integrates the following AISI standards into one document for easy reference, and thus supersedes all previous editions of these standards:.

Print this Page Design Documents.

s2211 Participants are eligible for 1. The scope was selected to provide coverage of the high volume application of cold-formed steel in light-framed construction. A new location for truss test methods, which were moved from Section E7 to Appendix 2. CFSEI members work together to develop and evolve industry standards and design methods, produce and issue technical bulletins, and provide seminars and online training 2s11 improve the knowledge and skills base of engineers and design professionals.

TOP Related Articles  EL RITUAL MAGICO DEL SANCTUM REGNUM ELIPHAS LEVI PDF

Free CFS Publications from the AISI/SMDI Construction Market Council –

The list of these standards, as well as other excellent design guides, are provided. Additional explanatory language is also provided. Yu, Wiley-Interscience Back to top. Special inspection of trusses over 60 feet 18 mm in length shall be in accordance with Section The design and installation of structural and nonstructural members utilized in cold-formed steel lightframe construction where the specified minimum base steel aiisi is not greater than 0.

The truss design drawings shall conform to the requirements of Section B2. AISI is comprised of 19 member companies, including integrated and electric furnace steelmakers, and approximately associate members who are suppliers to or customers of the steel industry.

Free CFS Publications from the AISI/SMDI Construction Market Council

LaBoube has an extensive background in the design and behavior of cold-formed steel structures. More information on the webinar and registration details s2111 available at www. It will include a review of overall buckling, local buckling, distortional buckling, and the applicable combinations of these limit states, as well as a discussion on bracing considerations for achieving overall stability.

Flexural Members Chapter E: This document is intended to serve only as an educational tool. For s21 information, visit www.